Applied Control - Emerson Impact Partner

Fisher Pilot Operated Regulators

Fisher® pilot operated regulators provide sensitive, accurate control of gas in fuel gas and commercial / industrial service applications to maintain a constant set outlet pressure even when inlet pressure fluctuations or variations in flow occur. Call 303-799-9300 to speak to an Application Engineer about sourcing the right pilot operated regulator for your project. If you are looking for a specific unit, please click here or call our office.
Fisher® Type 92B Self-Powered Control Valve
Instruction Manual Product Bulletin
Fisher® Type 92B Pressure Reducing Valve (PRV) is the standard steam valve for the industry. It can withstand dirty operating environments while providing accurate and stable pressure control. Type 92B steam valve is designed to provide decades of continuous service. Type 92B steam valve is applied as a main pressure reducing valve in industrial process heating applications such as heat exchangers, evaporators, digesters, and reactors.

Type 92B steam valve is diaphragm actuated, thus providing a simple, accurate, and easily maintained valve. Type 92B steam valve is rated for inlet pressures to 300 psig / 20,7 bar at 600°F / 316°C. The inlet (upstream) steam operates the pilot in this self-powered control valve.

Fisher® Type 92C Self-Powered Control Valve Instruction Manual Product Bulletin
Fisher® Type 92C self-powered control valve is a cost effective pressure reducing regulator used in steam service. This valve is available with a Type 6392 pilot or without a pilot for use as a pressure-loaded regulator. The pilot-operated version uses inlet pressure as the operating medium; no separate air supply is required. The pressure-loaded version is used where remote adjustment of the valve pressure setting is required.
Fisher® Type 92S Self-Powered Control Valve
Instruction Manual Product Bulletin
Fisher® Type 92S self-powered control valves are piston actuated for high cycle steam service. Type 92S control valves and pilot use lapped seating surfaces that have been proven to minimize seat leakage. Types 6492H and 6492L pilots have bellows sealed stems to eliminate stem guide friction.

The steel and stainless steel Type 92S control valves are available with a set point range of up to 250 psig / 17,2 bar and a maximum temperature of 650º F / 343º C.

Type 92S control valves can be used as a working monitor by adding a second Type 6492 pilot. The intermediate pressure must be high enough to meet the minimum differential pressure requirement of the second regulator. Pilot supply for the second regulator can be connected to the upstream system. When intermediate pressure may be too low (minimum differential pressure is pilot supply pressure minus outlet pressure).

These valves should be used with clear, dry or superheated steam.

Fisher® Type 92W Pressure Reducing Regulator
Instruction Manual Product Bulletin
Fisher Pilot Operated RegulatorFisher® Type 92W pressure-reducing regulator for liquid service includes either a Type 6492H or a Type 6492L pilot. This reliable, dependable regulator uses time-proven design concepts.

Pilot supply pressure is piped from the main valve inlet to the pilot inlet connection. Downstream pressure registers on the main valve pistons through the downstream control line and then on the pilot diaphragm.

Fisher® Type 99 Pressure Reducing Regulator
Instruction Manual Product Bulletin
Fisher® Type 99  gas regulator provides a broad capacity for controlled pressure ranges and capacities in a wide variety of distribution, industrial, and commercial applications.

Type 99 regulator has a Type 61L (low pressure), Type 61H (high pressure), or a Type 61HP (extra high pressure) pilot integrally mounted to the actuator casing. Type 99 regulator can handle up to 1000 psig / 69,0 bar inlet pressures (the 1000 psig / 69,0 bar regulator requires a Type 1301F pilot supply regulator and a Type H110 pop relief valve). The pilot supply regulator reduces inlet pressure to a usable 200 psig / 13,8 bar for the extra high pressure pilot. This regulator comes standard with O-ring seals on the guide bushing and valve carrier to keep main valve body outlet pressure from interfering with outlet pressure in the lower casing assembly.

Fisher® 299H Series Pressure Reducing Regulator
Instruction Manual Product Bulletin
Fisher® 299H Series 299H Series pressure reducing regulators provide a broad capacity for controlled pressure ranges and capacities in a wide variety of distribution, industrial and commercial applications. A 299H Series regulator has a pilot integrally mounted to the actuator casing. 299H Series regulators can handle inlet pressures up to 175 psi / 12,1 bar depending on orifice size.
Fisher® Type 310A Pressure Reducing Regulator
Instruction Manual Product Bulletin
Fisher® Type 310A fuel pressure regulator is used for high-pressure applications which require fast response such as fuel gas supply to a gas turbine or other large volume applications. Type 310A fuel pressure regulator includes one Type 32A pilot assembly mounted on the main valve for pressure reducing or wide-open monitoring applications.

Type 310A fuel pressure regulator has accurate control, tight shutoff, high capacity, reduce relief requirements and fast speed of response.

In addition, minimum installation space is required for the Type 310A fuel pressure regulator.

Fisher® Type 627F Pressure Reducing Regulator
Instruction Manual Product Bulletin
Fisher® Type 627F pilot-operated pressure reducing regulator provides superior performance when used in pressure factor measurement (fixed-factor billing) applications. Type 627F includes a factory-installed Type 6351F pilot and has external registration that requires a downstream control line.
Fisher® Types 1098-EGR and 1098H-EGR Pressure Reducing Regulators
Instruction Manual Product Bulletin
Fisher® Types 1098-EGR and 1098H-EGR regulators provide economical and accurate pressure control in a wide variety of applications; natural gas distribution systems; fuel gas supply to industrial boilers, furnaces, ovens, and mixers; and large commercial / industrial establishments such as shopping centers and schools. They are also used in plant air service and in liquid service where a slow stroking time (approximately 30 to 90 seconds) is desired on both opening and closing the main valve.
Fisher® CP200 Series Pressure-Loaded Pressure Reducing Regulators
Instruction Manual Product Bulletin
Fisher® CP200 Series pressure-loaded regulators have been engineered to fit a multitude of pressure-reducing applications including commercial and institutional installations. This flexibility is provided by the numerous body end connection sizes, outlet pressure settings, and orifice sizes. CP200 Series provides accurate control use in pressure-factor measurement (fixed-factor billing) applications.
Fisher® CP400 Series Pressure Loaded Pressure Reducing Regulator
Instruction Manual Product Bulletin
Fisher® CP400 Series pressure loaded regulators have been engineered to fit a multitude of pressure-reducing applications including light industrial and commercial installations, which include accurate control for use in pressure-factor measurement (Fixed factor billing) applications. This flexibility is provided by the numerous body end connection sizes, body materials, outlet pressure settings, orifice sizes, as well as the option for internal or external pressure registration. In addition to application flexibility, the CP400 Series offers multiple overpressure protection options to meet your application requirements.
Fisher® EZH and EZHSO Series Pressure Reducing Regulator
Instruction Manual Product Bulletin
Fisher® EZH and EZHSO Seriesregulators are accurate pilot-operated, pressure balanced, soft-seated regulators. They are designed for use in high pressure natural gas transmission/city gate stations, large capacity distribution systems, and power plant feeds. They provide smooth, reliable operation, tight shutoff and long life.
Fisher® EZL Series Pressure Reducing Regulator for Low Pressure Applications
Instruction Manual Product Bulletin
Fisher® EZL Series regulators are accurate pilot-operated, pressure balanced, soft-seated regulators. They are designed for use in natural gas distribution applications such as district regulating stations and commercial/industrial meter sets. They provide low differential, smooth, reliable operation, tight shutoff and long life.
Fisher® Type EZR Pilot Operated Regulator
Instruction Manual Product Bulletin
Fisher® Type EZR pilot-operated, pressure reducing regulator designed to give accurate, smooth, quiet operation, tight shutoff, and long life, even in dirty service. It is also available with a slam-shut device, the Type EZROSX, which can provide either overpressure protection or overpressure and underpressure protection by completely shutting off the flow of gas to the downstream sysytem. EZR Series can be installed in various applications such as natural gas transmission/distribution systems, industrial and commercial facilities.
Fisher® Type FL Pilot Operated Regulator
Instruction Manual Product Bulletin
Fisher® Type FL Series regulators are accurate pilot-operated, pressure balanced, soft seated regulators designed for high-pressure transmission/city gate, large capacity distribution systems, and power plant feeds. FL Series provides smooth and quiet operation, tight shutoff, and long life. The FL Series is now available with the new Type SRII Silencer on option, available also together with Type SRS, and suitable for extreme service conditions.
Fisher® Y690VB Series Vacuum Breaker
Instruction Manual Product Bulletin
Fisher® Y690VB Series vacuum breakers are used in applications where an increase in vacuum must be limited. When there is an increase in vacuum (decrease in pressure) beyond the setpoint on the diaphragm, it moves the disk away from the seat. This permits atmosphere or a positive pressure to enter the system and restore the controlled vacuum to its original vacuum pressure setting.
Fisher® Y692VB Series Vacuum Breaker
Instruction Manual Product Bulletin
Fisher® Y692VB Series  vacuum breakers are used in applications where an increase in vacuum must be limited. An increase in vacuum (decrease in absolute pressure) beyond a certain value registers on the diaphragm of the Y692VB Series, moving the disk away form the seat. This permits atmosphere or a positive pressure to enter the system and restore the controlled vacuum to its original pressure setting.
Fisher® Y695VR Series Vacuum Regulator
Instruction Manual Product Bulletin
Fisher® Y695VR Series vacuum regulators are used where a decrease in vacuum must be limited. A decrease in vacuum (increase in absolute pressure) on the diaphragm moves the disk away from the seat, allowing a higher vacuum source to return the system to the setpoint.
Fisher® Y696VR Series Vacuum Regulator
Instruction Manual Product Bulletin
Pilot Operated RegulatorsFisher® Y696VR Series vacuum regulators are used where a decrease in vacuum must be limited, such as between a tank and vacuum source to control vacuum in a tank. A decrease in vacuum (increase in absolute pressure) on the diaphragm moves the disk away from the seat, allowing a higher vacuum source to return the system to the setpoint.
Education | Request More Information

 

Comments are closed.

13705 Compark Blvd, Englewood, CO 80112
Phone: 303-799-9300 Fax: 303-799-1912

©2018 Applied Control. All rights reserved. Site Map | Terms & Conditions | Privacy | Disclaimer | Login